This site uses cookies. By continuing to browse the ConceptDraw site you are agreeing to our Use of Site Cookies.

mechanical engineering, mechanical design software, mechanical drawing symbols, mechanical drawing software Mechanical Engineering

mechanical engineering, mechanical design software, mechanical drawing symbols, mechanical drawing software
This solution extends ConceptDraw PRO v.9 mechanical drawing software (or later) with samples of mechanical drawing symbols, templates and libraries of design elements, for help when drafting mechanical engineering drawings, or parts, assembly, pneumatic,

Mechanical Drawing Software

It is impossible to imagine mechanical engineering without drawings which represent various mechanical schemes and designs. ConceptDraw PRO diagramming and vector drawing software supplied with Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park offers the set of useful tools which make it a powerful Mechanical Drawing Software.
This example engineering drawing showing the hydraulic directional control valve usage with floating motor and pressure compensated pump is redesigned using the ConceptDraw PRO diagramming and vector drawing software from the Wikimedia Commons file: DCV 17.jpg.
[commons.wikimedia.org/ wiki/ File:DCV_ 17.jpg]
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
[creativecommons.org/ licenses/ by-sa/ 3.0/ deed.en]
"Directional control valves are one of the most fundamental parts in hydraulic machinery as well and pneumatic machinery. They allow fluid flow into different paths from one or more sources. They usually consist of a spool inside a cylinder which is mechanically or electrically controlled. The movement of the spool restricts or permits the flow, thus it controls the fluid flow. ...
The spool (sliding type) consists of lands and grooves.The lands block oil flow through the valve body. The grooves allow oil or gas to flow around the spool and through the valve body. There are two fundamental positions of directional control valve namely normal position where valve returns on removal of actuating force and other is working position which is position of a valve when actuating force is applied. There is another class of valves with 3 or more position that can be spring centered with 2 working position and a normal position. ...
Directional control valves can be classified according to:
(1) number of ports;
(2) number of positions;
(3) actuating methods;
(4) type of spool." [Directional control valve. Wikipedia]
The fluid power equipment drawing example "Directional control valve" is included in the Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Hydraulic equipment schematic
Hydraulic equipment schematic, spring, variable spring, non-variable spring, reservoir, pressure compensator, hydraulic pump, four-port, flow path, four-port, crossed, flow path, flow path, floating motor, filter, electric linear, solenoid, dot, line, junction, closed path, closed port, callout, box, flow path,
The vector stencils library "Switches and relays" contains 58 symbols of electrical contacts, switches, relays, circuit breakers, selectors, connectors, disconnect devices, switching circuits, current regulators, and thermostats for electrical devices.
"In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.
The most familiar form of switch is a manually operated electromechanical device with one or more sets of electrical contacts, which are connected to external circuits. Each set of contacts can be in one of two states: either "closed" meaning the contacts are touching and electricity can flow between them, or "open", meaning the contacts are separated and the switch is nonconducting. The mechanism actuating the transition between these two states (open or closed) can be either a "toggle" (flip switch for continuous "on" or "off") or "momentary" (push-for "on" or push-for "off") type.
A switch may be directly manipulated by a human as a control signal to a system, such as a computer keyboard button, or to control power flow in a circuit, such as a light switch. Automatically operated switches can be used to control the motions of machines, for example, to indicate that a garage door has reached its full open position or that a machine tool is in a position to accept another workpiece. Switches may be operated by process variables such as pressure, temperature, flow, current, voltage, and force, acting as sensors in a process and used to automatically control a system. ... A switch that is operated by another electrical circuit is called a relay. Large switches may be remotely operated by a motor drive mechanism. Some switches are used to isolate electric power from a system, providing a visible point of isolation that can be padlocked if necessary to prevent accidental operation of a machine during maintenance, or to prevent electric shock." [Switch. Wikipedia]
"A relay is an electrically operated switch. Many relays use an electromagnet to mechanically operate a switch, but other operating principles are also used, such as solid-state relays. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal. The first relays were used in long distance telegraph circuits as amplifiers: they repeated the signal coming in from one circuit and re-transmitted it on another circuit. Relays were used extensively in telephone exchanges and early computers to perform logical operations.
A type of relay that can handle the high power required to directly control an electric motor or other loads is called a contactor. Solid-state relays control power circuits with no moving parts, instead using a semiconductor device to perform switching. Relays with calibrated operating characteristics and sometimes multiple operating coils are used to protect electrical circuits from overload or faults; in modern electric power systems these functions are performed by digital instruments still called "protective relays"." [Relay. Wikipedia]
The shapes example "Design elements - Switches and relays" was drawn using the ConceptDraw PRO diagramming and vector drawing software extended with the Electrical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Switch and relay symbols
Switch and relay symbols, two way contact, time delay make, open switch, time-delay closing, TDC, time delay make, normally open, time delay break, normally closed, time delay break, closed switch, time-delay opening, TDO, thermostat, temperature switch, temperature sensitive switch, temperature actuated switch, switch disconnector, isolating-switch, stay put, contact without spring return, spring return, make, spring return, break, spring return, shorting selector, make-before-break, shorting, bridging,  contact transfer, selector switch, break-before-make, nonshorting, nonbridging, contact transfer, safety interlock, circuit opening, relay contacts, relay coil, relay, pushbutton, make, circuit closing, mushroom head, push-pull head, pushbutton, break, circuit opening, mushroom head, push-pull head, pushbutton, 2-circuit, circuit opening, break, proximity limit switch, directly actuated, spring returned, normally closed, pressure actuated switch, pilot light, passing make-contact, mercury switch, manual switch, manually operated switch, make contact, liquid level actuated switch, limit switch, directly actuated, spring returned, normally open, limit switch, directly actuated, spring returned, normally closed, limit switch, isolator, inertia switch, gas flow actuated switch, fuse, flow actuated, circuit breaker, change-over contact, break contact, SPST, single-pole, single-throw, switch, SPDT, single-pole, double-throw, switch, DPST, double-pole, single-throw, switch, DPDT, double-pole, double-throw, switch, 4 position, switch, 3 position, three-position, switch, 2 position, switch,
The vector stencils library "Valve assembly" contains 141 symbols of pressure and flow regulators, flow direction indicators, controls, and symbols to design flow paths of control valves.
Use these valve assembly shapes to design the engineering drawings of hydraulic and pneumatic valve assemblies in fluid power systems.
"Control valves are valves used to control conditions such as flow, pressure, temperature, and liquid level by fully or partially opening or closing in response to signals received from controllers that compare a "setpoint" to a "process variable" whose value is provided by sensors that monitor changes in such conditions.
The opening or closing of control valves is usually done automatically by electrical, hydraulic or pneumatic actuators. Positioners are used to control the opening or closing of the actuator based on electric, or pneumatic signals.
A control valve consists of three main parts in which each part exist in several types and designs: Valve's actuator, Valve's positioner, Valve's body.
" [Control valves. Wikipedia]
The shapes example "" was created using the ConceptDraw PRO diagramming and vector drawing software extended with the Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Valve assembly symbols
Valve assembly symbols, variable arrow, valve, two-position, ports, valve, two-position, five ports, valve, three-position, ports, valve, three-position, five ports, valve, four-position, ports, valve, four-position, five ports, two-port, flow path, two-port, closed, flow path, three-port, flow path, three-port, crossover, flow path, spring, variable spring, non-variable spring, shaft, rod, shaft, direction, rotation, rotary connection, line junction, roller, one-way trip, rod, restriction, fluid flow, pull, push, button, pneumatic, fluid flow, plunger, variable plunger, non-variable plunger, pilot-operated, pedal, treadle, over - center, manual override, manual operation, lever, latch, junction, crossing, indication, temperature, temperature control, hydraulic, fluid flow, four-port, tandem, flow path, four-port, semi-connected, flow path, four-port, open, flow path, four-port, flow path, four-port, crossover, flow path, four-port, crossed, flow path, four-port, closed, flow path, fluid energy, pneumatic, hydraulic, energy source, fluid energy, pneumatic, energy source, fluid energy, hydraulic, energy source, flow path, flexible line, five-port, flow path, five-port, crossover, flow path, five-port, closed, flow path, electric, electrical, functional element, electric rotor, electric linear, solenoid, dot, line, junction, detent, curved arrow, direction, rotation, closed path, closed port, box, flow path, arrow, flow path, direction, rectilinear motion, air exhaust port, air bleed, connection,
"A hydraulic circuit is a system comprising an interconnected set of discrete components that transport liquid. The purpose of this system may be to control where fluid flows (as in a network of tubes of coolant in a thermodynamic system) or to control fluid pressure (as in hydraulic amplifiers).
... hydraulic circuit theory works best when the elements (passive component such as pipes or transmission lines or active components such as power packs or pumps) are discrete and linear. This usually means that hydraulic circuit analysis works best for long, thin tubes with discrete pumps, as found in chemical process flow systems or microscale devices." [Hydraulic circuit. Wikipedia]
The engineering drawing example "Hydraulic circuits" was redrawn using ConceptDraw PRO diagramming and vector drawing software from the Wikimedia Commons file: Hydraulic circuits.png.
[commons.wikimedia.org/ wiki/ File:Hydraulic_ circuits.png]
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
[creativecommons.org/ licenses/ by-sa/ 3.0/ deed.en]
The engineering drawing example "Hydraulic circuits" is included in the Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Hydraulic circuit schematic
Hydraulic circuit schematic, variable arrow, spring, variable spring, non-variable spring, shaft, rod, pump, hydraulic, oil tank, non-return, valve, junction, crossing, four-port, three-position, valve, fixed displacement hydraulic pump, fixed displacement hydraulic motor, dot, line, junction, callout, box, flow path, arrow, flow path, direction, rectilinear motion,